Toll-free Information Service
1.800.263.5803
Select Page

Corentium Pro CRM Calibration Service

Corentium Pro Image, Courtesy of Airthings

The Radiation Safety Institute is now offering calibration services to Corentium Pro continuous radon monitor users.   The Institute’s National Laboratory in Saskatoon is the only C-NRPP and NRPP certified Radon Reference Laboratory in Canada offering performance testing and calibration services for Corentium Pro CRMs.

Why use the Canadian Calibration Services?

With lower nominal base prices, favourable exchange rate and  complete elimination of brokers fees– there is no reason to delay giving our CRM calibration service a try. For Canadian clients it will deliver up to 60% of savings compared to competition.

 Regular Service Fee

Calibration …………………….CDN$185/ monitor ( singe device)

Calibration …………………….CDN$160/ monitor ( group of 3 devices)

Discounted Service Fee 

Calibration …………………….CDN$135/ monitor

Discounted Service is only available on the first business day of March and the first business day of September. Your unit(s) must be at the lab at these exact dates. Regular service fee will apply to unit(s) delivered too late.

* Shipping and taxes not included

Calibration Process

Corentium Pro CRMs sent to the Institute are first inspected, and then placed in our radon chamber for a performance test.  The instruments are exposed for a predetermined time and the measured radon concentrations compared against our reference system.

CRMs that agree with our reference system to within +/-25% are considered to be operating properly.  Instruments that fail the performance test are tested a second time to confirm the results.  As necessary, the Institute will modify instrument internal calibration factors and then confirm the instrument’s performance.   The Institute will contact Sun Nuclear for guidance and support for any instruments that appear to be malfunctioning.  Upon completion of a successful performance test, the calibration date is updated on all CRMs as appropriate.  For all performance tests, the Institute places a calibration sticker on the device and provides the client with an instrument performance report.

For instruments that are determined to be malfunctioning, the Institute will work with the client to determine how they wish to proceed with repairs.  This could include the Institute forwarding the instrument to Sun Nuclear directly for repair on their behalf.

C-NRPP Quality Assurance Requirements

In accordance with the C-NRPP quality assurance requirements CRMs should be tested once a year. An annual performance test ensures your CRM is working properly and provides confidence that you are providing your clients with accurate test results and advice.  Annual performance tests also protect radon measurement professionals from unnecessary liabilities.

The exclusive agreement between Sun Nuclear and RSIC was put in place to streamline calibration services for hundreds of Sun Nuclear CRM users in Canada.  With RSIC National  laboratories, the only C-NRPP certified radon chamber service provider in Canada,  it has never been easier or more economical to calibrate your continuous radon monitors. Using our RSIC Calibration services you reduce your turn around times and idling in your business while the device is being serviced, you avoid all cross border shipment hassles and eliminate exchange rate risks.

Using our service is easy

  1. Download and fill out this form. Include it with your shipment to the RSIC National Laboratories
  2. We shall invoice you upon service completion

Download the Form


Questions?

Call us at 1-800-263-5803 (option 4) or (306) 975-0566 ext. 224
Fax: (306) 975-0494
Email us at: chamber@radiationsafety.ca

Related Links

  1. Radon Chamber Reference Laboratory Services
  2. Home Radon Testing